Dimensions:
1.75" (4.45cm) H
19" (48.26cm) W
12" (30.48cm) D
Operating Temperature:
0° to 40° C
Power Requirements:
100 to 240VAC, 47–63Hz, 1A;
Power entry module with standard, grounded power cord supplied;
1A fuse protection
Connectivity:
Ethernet connection to ARC Plus
Channel Capacity:
16 status, 8 metering, 6 command channels
Metering Input Range:
> 99.75% accuracy, full scale
Status Input Range:
> 0 to +28VDC or switch closure
Output Types:
C, NO, NC relay outputs;
momentary or latching;
5A, 240VAC