Climate Guard


Protect your Equipment and Data

Environmental problems in the server room can cause costly downtime, damage expensive equipment, and even lead to loss of mission-critical data. HVAC equipment failure, power outages, and simple human error can cause catastrophic IT problems—especially after hours. Server rooms and data centers of all sizes require comprehensive monitoring of environmental conditions to detect a problem as early as possible.

Climate Guard monitors temperature, humidity, flood/leak, and many other conditions that can cause serious IT disasters. Email, SMS and SNMP notifications ensure that responsible personnel can respond quickly and effectively.

Watch for Early Warning Signs

Not all problems happen suddenly. A change in how equipment behaves over time may be an early warning sign of a serious problem. A gradual rise in temperature or a change in sound level may be evidence of impending equipment failure. Climate Guard’s onboard charting allows you to watch for changes in environmental conditions over time, preventing a problem from becoming a crisis.

A Monitoring Solution that Grows with your Needs

Climate Guard’s unique modular design allows you to add capacity and features as you need them. Easily add new sensors as you add equipment, and take advantage of new functionality when you need it.

Climate Guard can support up to a total of 64 sensors, including 3 built-in sensors, 8 switch inputs connected to the rear panel connector, 8 powered switch inputs and up to 45 digital sensors connected in daisy-chain configuration to the front panel sensor ports. One or two optional modules can be installed in the front of the Climate Guard unit to simplify daisy-chain wiring and/or to increase the number of switch inputs or powered switch inputs, up to an overall total of 64 sensors.

Climate Guard LT is a convenient package providing up to a total of 32 sensors including 3 built-in sensors, 8 powered switch inputs and up to 21 digital sensors connected in daisy-chain configuration to the front panel sensor ports.

See Climate Guard in action: Check out our live demo. (Username: demo, Password: demo)

Dimensions:

1.75" (4.45cm) H x 19" (48.26cm) W x 5" (12.7cm) D

Operating Temperature:

-40 to 50° C

Power Requirements:

12VDC, 1A

Ethernet:

10/100 full or half duplex

Maximum Sensors:

Climate Guard

64 sensors:

  • 3 built-in sensors (temperature, light and sound)
  • 45 digital sensors (with daisy-chaining)
  • 8 powered switch inputs
  • 8 switch inputs

Climate Guard LT

32 sensors:

  • 3 built-in sensors (temperature, light and sound)
  • 21 digital sensors (with daisy-chaining)
  • 8 powered switch inputs

Expansion Modules (Climate Guard only):

Up to two expansion modules

Front Panel LEDs:

Power, Fault; Ethernet RJ45 LEDs: Link, Activity

Digital Sensor Inputs:

8 built-in ports for digital sensors and powered switch inputs

Switch Inputs (Climate Guard only):

8 switch inputs for contact closures

Built-In Sensors:

Temperature, sound, light

Protocols

HTTP, HTTPS, SMTP, SMTP/SSL, SNMP v1, SNTP

Climate Guard Climate Guard LT
Email/SMS Alerts
Built-in web server
Web-based charting
SNMP
Max sensors 64 32
Built-in sensors Temperature
Light
Sound
Temperature
Light
Sound
Digital sensors 45* 21*
Powered switch inputs 8 8
Switch inputs 8 0
Max expansion modules 2 0

* Daisy-chaining allows installation of maximum number of digital sensors.

TEMP-INDOOR Sensor

Part #: TEMP-INDOOR

The TEMP-INDOOR Sensor is a general-purpose, digital, indoor temperature sensor tailored for monitoring ambient temperatures within a room or in an equipment rack. Temperature accuracy: ±0.5° C from -10° C to 85° C. Cables are not supplied with this sensor. Order 25’ RJ-12 cable, part number SENSOR CABLE.

For use with Climate Guard and Plus-X EM Environmental Monitors, ARC Plus systems equipped with a Plus-X EM unit, and ARC Solo systems equipped with the STM-4D Temperature Module option.

TRI-TEMP Sensor Array

Part #: TRI-TEMP

TRI-TEMP is ideal for monitoring heat rise in equipment racks. Three temperature sensors are pre-wired in series at 3’ intervals for mounting at the bottom, middle and top of a rack to provide a real-time temperature profile. A single 12’ pigtail is provided to connect TRI-TEMP to Burk Climate Guard, Plus-X EM or STM-4D. Temperature accuracy: ±0.5° C from -10° C to 85° C.

For use with Climate Guard and Plus-X EM Environmental Monitors, ARC Plus systems equipped with a Plus-X EM unit, and ARC Solo systems equipped with the STM-4D Temperature Module option.

TEMP-OUTDOOR Sensor

Part #: TEMP-OUTDOOR

The TEMP-OUTDOOR digital temperature sensor is intended for outdoor or indoor monitoring of equipment or ambient temperatures. Temperature accuracy: ±0.5° C from -10° C to 85° C. The TEMP-OUTDOOR sensor is attached to 25’ of cable with an RJ-12 connector on the end. The sensor has a mounting ring and gasket to accommodate #6 or #8 hardware. The sensing elements are sealed for added protection from dirt and moisture. 

For use with Climate Guard and Plus-X EM Environmental Monitors, ARC Plus systems equipped with a Plus-X EM unit, and ARC Solo systems equipped with the STM-4D Temperature Module option.

TEMP-STACK Sensor

Part #: TEMP-STACK

The TEMP-STACK Sensor is a digital stack temperature sensor designed for sensing heat within the air ducting of your equipment. Temperature accuracy: ±0.5° C from -10° C to 85° C. The TEMP-STACK Sensor is attached to 25’ of cable with an RJ-12 connector. The sensor is mounted in the tip of a 3/8” diameter chrome tube. The supplied mounting hardware consists of a base and a compression fitting to allow the sensor to be secured at variable depths. This allows the installer to locate the sensor up to 9 1/2” from the equipment wall, well within the airflow being monitored.

For use with Climate Guard and Plus-X EM Environmental Monitors, ARC Plus systems equipped with a Plus-X EM unit, and ARC Solo systems equipped with the STM-4D Temperature Module option.

TEMP-WALLMOUNT Sensor

Part #: TEMP-WALLMOUNT

The TEMP-WALLMOUNT Sensor is housed in a 2 5/8” x 5” enclosure with air vents to facilitate sensing of the environment. Temperature accuracy: ±0.5° C from -10° C to 85° C. A 14’ cable is provided with an RJ-12 connector on one end. The TEMP-INDOOR has a large, easy to connect barrier strip that accommodates flat or Phillips type screwdrivers.

For use with Climate Guard and Plus-X EM Environmental Monitors, ARC Plus systems equipped with a Plus-X EM unit, and ARC Solo systems equipped with the STM-4D Temperature Module option.

Humidity Sensor

Part #: HUMIDITY SENSOR

Combined digital humidity and temperature sensor. Humidity range from 0–100% RH. Temperature accuracy for Humidity Sensors Rev C and above is ±0.5° C from -10° C to 85° C. Requires Digital Sensor Cable.

For use with Climate Guard and Plus-X EM Environmental Monitors and ARC Plus systems equipped with a Plus-X EM unit.

Motion Sensor

Part #: MOTION SENSOR

Motion Sensor. Includes pre-wired 14' cable with 6 pin modular RJ12 (6P6C) connector.

Smoke Detector

Part #: SMOKE DETECTOR

Smoke Detector for use with Climate Guard or Plus-X EM series. For use as a supplemental smoke detector only. Includes pre-wired 14' cable with 6 pin modular RJ12 (6P6C) connector.

Flood Detector

Part #: FLOOD DETECTOR

Flood/Water Detector for Climate Guard or Plus-X EM series. Requires Digital Sensor Cable.

Magnetic Door Contact

Part #: DOOR CONTACT

Magnetic surface mount switch for windows and doors to indicate closed or open position. Requires 2-conductor cable

Digital Sensor Cable

Part #: SENSOR CABLE

25' RJ12 (6P6C) cable with crossover wiring for use with Climate Guard or Plus-X EM series digital sensors.

Digital Daisy-Chain Sensor Cable

Part #: SENSOR CABLE - DAISY CHAIN

25' RJ12 (6P6C) cable with straight-through wiring. Use with Burk Technology RJ12 Splitter to daisy-chain digital temperature or humidity sensors with Climate Guard or Plus-X EM Environmental Monitors.

Powered Switch Input Cable

Part #: PWR INP CABLE

14' RJ12 (6P6C) cable with an RJ-12 connector on one end and terminal lugs on the other end.

RJ12 (6P6C) Phone Line Coupler

Part #: RJ12 COUPLER

RJ12 (6P6C) coupler with crossover wiring for connecting cables used with Climate Guard or Plus-X EM series.

RJ12 (6P6C) Phone Line Splitter

Part #: RJ12 SPLITTER

RJ12 (6P6C) splitter with straight-through wiring for daisy-chaining temp sensors used with Climate Guard or Plus-X EM series.

Switch Input Module

Part #: SWCH INP MODULE

Adds 8 additional switch inputs for Climate Guard 64 or Plus-X EM64, allowing use of additional 2-conductor sensors such as door contacts, etc.

8 Input Sensor Module

Part #: SENSOR MODULE

Adds 8 additional sensor inputs to the Climate Guard 64 or Plus-X EM64, allowing use of additional temperature, humidity and powered switch input sensors.


Ordering information

Part #Product
CLIMATE GUARDClimate Guard Environmental MonitorRequest quote

Supports up to 64 sensors.

CLIMATE GUARD LTClimate Guard LT Environmental MonitorRequest quote

Supports up to 32 sensors.

CG STARTER KITClimate Guard Starter KitRequest quote

Includes Climate Guard Unit, 1 flood detector, 1 humidity sensor, 2 temperature sensors and 4 sensor cables.

Key Features

  • Built-in temperature, light and sound sensors
  • Easily expandable with external sensors
  • Integrates with IP security cameras
  • Alert personnel via email, SMS and SNMP traps.
  • Spot trends and prevent problems from developing with onboard charting.
  • Onboard web interface for setup, monitoring and access to historical data and charts